Related Case Studies
EWWS-DZ
Water-cooled chiller for indoor installation equipped with premium efficiency oil-free centrifugal compressor and low GWP refrigerant R-513A
- Cooling capacity:
- 320 - 2175 kW
- Heating capacity:
- 337 - 1950 kW
- Refrigerant:
- R-513A
- Compressor:
- Centrifugal oil free
Water to water Modular heat pump
Water to Water Chiller, Heat Pump and Condenserless
- Cooling capacity:
- 100 - 160 kW
- Heating capacity:
- 100 - 160 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWAD-TZ-B
Air cooled Inverter Screw chiller - the best choice from small to large applications
- Cooling capacity:
- 169 - 1104 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWAH TZ-B
Air cooled Screw chiller with Daikin Inverter technology - the best choice for your plant & the environment
- Cooling capacity:
- 170 - 1064 kW
- Refrigerant:
- R-1234ze
- Compressor:
- Screw
EWAD-T-(B)(C)
Air Cooled Screw Chiller - with extended range to meet any buildings capacity requirement
- Cooling capacity:
- 290 - 2148 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWAT-B
World's 1st Air Cooled chiller with R-32 refrigerant and scroll compressor technology
- Cooling capacity:
- 81 - 701 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWAQ-AC
Air Cooled Chiller for light commercial and low temperature applications using scroll technology and R-410A refrigerant
- Cooling capacity:
- 5.2 - 15.7 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
EWAD-CF
Free Cooling Air Cooled chiller - helping your Return On Investment
- Cooling capacity:
- 602 - 1555 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWYQ-AC
Air cooled heat pump for outdoor installation equipped with scroll compressor and R-410A refrigerant
- Cooling capacity:
- 9 - 13 kW
- Heating capacity:
- 11.2 - 13.9 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
EWYD-BZ
Air cooled Inverter Screw Heat Pump - the wise choice for your building
- Cooling capacity:
- 247 - 580 kW
- Heating capacity:
- 271 - 618 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWWD-VZ
Water coooled Inverter Screw chiller & heat pump - the highest peak in Applied solutions
- Cooling capacity:
- 449 - 2074 kW
- Heating capacity:
- 550 - 2500 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWWH-VZ
Water coooled Inverter Screw chiller & heat pump - top-class efficiency with low environmental footprint
- Cooling capacity:
- 329 - 1540 kW
- Heating capacity:
- 409 - 1924 kW
- Refrigerant:
- R-1234ze
- Compressor:
- Screw
EWWD-DZ
Water cooled chiller for indoor installation equipped with premium efficiency oil free centrifugal compressor and compact footprint
- Cooling capacity:
- 320 - 2173 kW
- Refrigerant:
- R-134a
- Compressor:
- Centrifugal oil free
EWWH-DZ
Water cooled chiller for indoor installation equipped with premium efficiency oil free centrifugal compressor and a compact footprint
- Cooling capacity:
- 230 - 1415 kW
- Heating capacity:
- 238 - 1200 kW
- Refrigerant:
- R-1234ze
- Compressor:
- Centrifugal oil free
EWWQ-G/L
Water cooled scroll compressor chiller and heat pump using R-410 refrigerant
- Cooling capacity:
- 91 - 722 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
EWHQ-G
Compact water cooled scroll compressor chiller & heat pump using R-410 refrigerant
- Cooling capacity:
- 90 - 370 kW
- Heating capacity:
- 110 - 440 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
DWSC
Water Cooled Centrifugal Chiller - Single or dual compressor options for large applications using R134a, R-513a or R1234ze refrigerant
- Cooling capacity:
- 1050 - 4500 kW
- Compressor:
- Centrifugal
DWDC
Water Cooled Centrifugal Chiller - Dual compressor suitable for large applications using R-134a, R-513a or R1234ze refrigerant
- Cooling capacity:
- 1500 - 9000 kW
- Compressor:
- Centrifugal
WCT
Water Cooled Centrifugal Chiller - industry leading solution for District Cooling applications, using R134a refrigerant
- Cooling capacity:
- 7750 - 11400 kW
- Refrigerant:
- R-134a
- Compressor:
- Centrifugal
EWLQ-G
Water cooled scroll compressor condenserless chiller using R-410 refrigerant
- Cooling capacity:
- 85 - 350 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
EWLQ-L
Water cooled scroll compressor condenserless chiller using R-410 refrigerant
- Cooling capacity:
- 170 - 680 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
EWLQ-KC
Condenserless water cooled chiller using scroll compressor technology and R-410 refrigerant
- Cooling capacity:
- 14 - 64 kW
- Refrigerant:
- R-410A
- Compressor:
- Scroll
Professional
Flexible Air Handling Unit for custom applications
Modular R
High-end Air Handling Unit solution with heat recovery
Modular P
Air Handling Unit with plate heat exchanger
DoS Daikin on Site
Daikin on Site is an innovative remote monitoring tool for chiller plants and air handling units, providing information with a unique level of detail. It offers a constantly evolving...
EWAD TZ-C
Air Cooled single screw chiller using Daikin Inverter technology and variable frequency drive - using R-134a refrigerant - with total heat recovery
- Cooling capacity:
- 712 - 1965 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWAH TZ-C
Inverter driven single screw compressor with variable frequency drive featuring full/partial heat recovery - using R-1234ze refrigerant
- Cooling capacity:
- 712 - 1965 kW
- Refrigerant:
- R-1234ze
- Compressor:
- Screw
EWYT-B-
Daikin's innovative R-32 Heat Pump is the first air cooled heat pump in its range, with low environmental impact and outstanding reliability
- Cooling capacity:
- 74 - 610 kW
- Heating capacity:
- 82 - 650 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWWD-J
- Cooling capacity:
- 119 - 284 kW
- Heating capacity:
- 144 - 347 kW
- Refrigerant:
- R-134a
- Compressor:
- Screw
EWWH-J
Water cooled heat pump using screw technology with compact design for retrofit and indoor installation using low GWP refrigerant
- Cooling capacity:
- 88 - 201 kW
- Heating capacity:
- 106 - 243 kW
- Refrigerant:
- R-1234ze
- Compressor:
- Screw
EWWS-J
Water cooled heat pump using screw technology with compact design for retrofit and indoor installation using R-513A refrigerant
- Cooling capacity:
- 115 - 272 kW
- Heating capacity:
- 140 - 338 kW
- Refrigerant:
- R-513A
- Compressor:
- Screw
EWAT-CZ
Air-cooled scroll chiller equipped with full inverter technology and R-32 refrigerant
- Cooling capacity:
- 16 - 90 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWYT-CZ
Air-cooled scroll chiller and heat pump equipped with full inverter technology and R-32 refrigerant
- Cooling capacity:
- 16 - 90 kW
- Heating capacity:
- 16 - 90 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWWS-VZ
- Cooling capacity:
- 440 - 2046 kW
- Heating capacity:
- 525 - 2443 kW
- Refrigerant:
- R-513A
- Compressor:
- Screw
EWAT-B-C
The new generation of Daikin Air-cooled scroll chillers equipped with R-32 refrigerant
- Cooling capacity:
- 252 - 1012 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
EWFT-B-C
The new generation of Daikin Air-cooled scroll chillers equipped with R-32 refrigerant and Free Cooling
- Cooling capacity:
- 252 - 1012 kW
- Refrigerant:
- R-32
- Compressor:
- Scroll
TZ-D - Free Cooling
The new generation of Daikin Air-cooled screw inverter chillers equipped with R-1234ze. R-513A and R134a refrigerants and Free Cooling
- Cooling capacity:
- 150 - 1950 kW
- Refrigerant:
- R-134a, R-513A or R-1234ze
- Compressor:
- Screw
TZ-D
The new generation of Daikin Air-cooled screw inverter chillers equipped with R-1234ze, R-513A and R134a refrigerants
- Cooling capacity:
- 150 - 1950 kW
- Refrigerant:
- R-134a, R-513A or R-1234ze
- Compressor:
- Screw